website Skip to content
+33 (0)4 34 11 24 58
WELCOME TO TUBEO.COM
|
English
  • Language FrançaisFrançais
  • Language EnglishEnglish
  • Language NederlandsNederlands

Search

INTERCLAMP - Interclamp brand fittings on tubeo.com

INTERCAMPS fittings

Interclamp brand fittings: thanks to Interclamp tubular fittings, easily create ultra-strong temporary or permanent constructions. Each part can support an axial load of 500kg per stop screw * (only for the Interclamp brand), for a screw tightened with a torque of 40Nm (obtained with a ratchet wrench). Fittings are malleable cast iron (BS EN 1562:1997), hot dipped galvanized (BS EN ISO 1461:2009) covered with a zinc coating (Double protection against corrosion). They are TÜV certified, delivered as quickly as possible within 5/7 working days in France and Europe at fixed rates.

raccords interclamp

Interclamp brand:

Produced from malleable cast iron (BS EN 1562:1997) .
Hot-dip galvanized (BS EN ISO 1461:1999) .
Double corrosion protection (zinc finish) .
Screw protection: Stainless steel with cutting edge.
26.9mm, 33.7mm, 42.4mm, 48.3mm, 60.3mm.
Axial load per stop screw: 500kg / 40Nm* .
Possibility of powder-coating the fittings.
Range of fittings for PMR: Yes .
TUV certified approved connection.
Connection thickness: 4.5 - 5.5mm.
Production time (2/3 days) .
Fast delivery (48/72 hours) .
20-year anti-corrosion guarantee.
5 year fitting guarantee.
Sold individually: Yes .


1 - Horizontal load capacity tables:

Horizontal load capacity table tested on 2 BS EN 1387 galvanized steel tubes (tube diameter defined in table) with INTERCLAMP fittings. Values ​​are in kg. The theoretical load table is only given as an indication of the loads that may apply to tubular uprights, which is normally the limiting factor in handrail design.

Shelving and structures in general can be built using different tubular connections. Care must be taken to ensure that the size and diameter of the tube chosen is adequate for the anticipated loads. To assist in the selection of the correct tube, Table 1 provides the uniformly distributed loads that can be supported between vertical posts, assuming that the load is supported by two horizontal tubes. These loads are calculated based on the maximum bending movement of the tube.

Caution: When designing structures, care must be taken to ensure that the load on each grub screw does not exceed 500 kg .

Crossbar length 33.7mm (3.2mm) 42.4mm (3.2mm) 48.3mm (3.2mm)
0.6m 900kg 1450kg 1750kg
0.8m 650 kg 1100 kg 1400 kg
1.0m 550 kg 900kg 1150kg
1.2m 450 kg 666kg


2 - Vertical load capacity tables:

Vertical load capacity table tested on 1 BS EN 1387 galvanized steel tube (tube diameter defined in table) with INTERCLAMP fittings. Values ​​are in kg. The following table presents the load capacities on a vertical tube with length as a variable. The values ​​are based on the compression force and buckling load of the hollow tubes.

The theoretical load table is only given as an indication of the loads that may apply to tubular uprights, which is normally the limiting factor in handrail design.

Tube length 33.7mm (3.2mm) 42.4mm (3.2mm) 48.3mm (3.2mm)
0.3m 3000kg 4050 kg 5000kg
0.6m 2000kg 3050kg 3800 kg
0.9m 1200 kg 2050 kg 2800 kg

* The theoretical loads of the various tubular connections are given for information purposes only. Care should be taken to ensure that the size and diameter of the fitting chosen is adequate for the anticipated loads.
** The spacing distances between two vertical tubes are given for information only. Care must be taken to ensure that the size and diameter of the tube chosen is adequate for the anticipated loads.
*** Please refer to paragraph 1.20 - RESPONSIBILITY AND OBLIGATION in our conditions of sale.